Acrel Adw210-D10-1s Modular Multi Loop AC Multi Circuit Iot DIN Rail Electricity Power Meter Energy Meter

Acrel Adw210-D10-1s Modular Multi Loop AC Multi Circuit Iot DIN Rail Electricity Power Meter Energy Meter

Product Description ADW210-D10-1S lcd display three phase multi channel smart IOT wireless modular submetering energy me;
Basic Info
Model NO. ADW210-D10-1S
Measured Signal Continuous Wave
Type Energy Meter
Certification RoHS, ISO, CE
Customized Non-Customized
Product Name Three Phase Multi Channel Energy Meter
Auxiliary Power AC/DC 85V~265V
Frequency 45~65Hz
Input Voltage AC 3*220V/380V
Input Curernt AC 5A, 100A, 400A, 600A
Accuracy Class 0.5
Communication RS485, Modbus-RTU
Transport Package Fob Shanghai
Trademark ACREL
Origin China
Production Capacity 1000PCS/Per Month
Product Description

ADW210-D10-1S lcd display three phase multi channel smart IOT wireless modular submetering energy meterGeneral

ADW2XX series rail type multi-loop power meters are mainly used for measuring the full electric parameters of multiple three-phase circuits,Up to four three-phase loop current inputs can be connected simultaneously.It Can measure voltage and current, power, power factor, phase angle, unbalance, harmonic and other parameters.

Function1.Full electric parameter measurement of N(1,2,3,4) three-phase circuit,externalCurrent transformer;2.Monitoring three Phase Voltage/Current,Zero sequence Current,Frequency;3.Monitoring three Phase power ,total power (active,reactive,apparent);4.Monitoring three Phase power-factor,totalpower-factor;5.Monitoring Voltage/Current Phase Angle,Voltage/Current Degree of unbalance;6.Monitoring Voltage,Current total Harmonic and 2-31 Fractional harmonics;7.Record of voltage,current and power extremum of current month and last month;8.Maximum Current,Maximum power demand and real time Current,real time power demand;9.200 event records,Record the action of DIDO;10.Support over-voltage, over-current, phase failure,DI linkage and other alarm output;11.4 time zones 14Periods rate setting;12.Four quadrant electric energy,12-month multi rate electric energy;13.31 days four quadrant and multi rate electric energy freezing,Positive and negative energy metering;14.2 channel Switching inputs,2 channel Switching outputs,RS485,Active pulse output(Switchable corresponding circuit).The following auxiliary functions can be extended through its RJ45 interface:15.(MK) 12 channel Switching inputs+4 channel Switching outputs;16.(MTL) 12 channel external NTC temperature +4 channel residual current measurement (leakage current);17.(AWT100-2G) 2G Wireless Communication18.(AWT100-4G) 4G Wireless Communication19.(AWT100-NB) NB-IoT Wireless Communication20.(AWT100-LoRa) LoRa Wireless Communication21(AWT100-LW) LoRaWAN Wireless Communication
Technical Parameters(Meter)
Auxiliary powerAC/DC 85~265V;consumption≤10VA;

 


input
Frequency45~65Hz;


Voltage
AC 3×220V/380V;
Overload: 1.2 times of rated value (continuous); 2 times of ratedvalue / 1s;
Power consumption:≤ 0.5VA;


Current
AC 5A,100A,400A,600A;(External opening transformer)
Overload: 1.2 times of rated value (continuous); 10 times of ratedvalue / 1s;
Power consumption:≤ 0.5VA;
measurement accuracyFrequency 0.05Hz, voltage and current 0.5 level, active electricenergy level 1, reactive electric energy level 2;
2-31 times harmonic accuracy: ± 1%;


Features
Pulse outputOutput mode: optocoupler pulse with open collector;
CommunicationRS485,Modbus-RTU;Baud rate 1200~38400;
Switchin ginputDry contact input,Built in power supply;
outputOutput mode:Relay normally open contact output;contact rating:AC 250V/3A DC 30V/3A;

Technical Parameters(Module)


Switching Module
PowerRJ45 interface,DC 12V,Power consumption≤1W;
CommunicationRJ45 interface,Modbus-RTU;(Communication with the main Part)
Switching inputDry contact input,Built in power supply;
Switching outputOutput mode:Relay normally open contact output;contact rating:AC 250V/3A DC 30V/3A;

 

Temperature and leakage module
PowerRJ45 interface,DC 12V,Power consumption≤1W
CommunicationRJ45 interface,Modbus-RTU;(Communication with the main Part)
temperaturemeasurement-20~100ºC;
Leakage measurement10~3000mA;
measurement accuracytemperature ±2ºC,Leakage1.0%;

Other Parameters

Safety
Power frequencywithstand voltage>AC 2kV/1min;
Insulation resistance>100MΩ;


Environment
working temperature:-20ºC~+60ºC; Storage temperature:-40ºC~+70ºC; relative humidity:≤95% No condensation; Altitude:≤2500m;
electromagnetic compatibilityBetter than grade 3;

Dimension(Unit:mm)
ADW2xx series main part dimension
Module dimension

Acrel Adw210-D10-1s Modular Multi Loop AC Multi Circuit Iot DIN Rail Electricity Power Meter Energy Meter


Dimension(CT)

Acrel Adw210-D10-1s Modular Multi Loop AC Multi Circuit Iot DIN Rail Electricity Power Meter Energy Meter


Installation

Acrel Adw210-D10-1s Modular Multi Loop AC Multi Circuit Iot DIN Rail Electricity Power Meter Energy Meter


Wiring

Acrel Adw210-D10-1s Modular Multi Loop AC Multi Circuit Iot DIN Rail Electricity Power Meter Energy Meter

Acrel Adw210-D10-1s Modular Multi Loop AC Multi Circuit Iot DIN Rail Electricity Power Meter Energy Meter

 

Quotation

 


Send inquiry