Dtsd1352-C Three Phase Energy Power Meter for Solar PV Sungrow Inverter Sg30cx*, Sg50cx, Sg110cx
Basic Info
Model NO. | DTSD1352-C |
Installation | Direct Connected |
Usage | Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter |
Electric Equipment | Three-phase Four-wire |
Theory | Static Meter |
Power Meter Connection | Terminal |
Measured Signal | Continuous Wave |
Type | Energy Meter |
Certification | RoHS, CE |
Customized | Customized |
Phase | Three Phase |
Accuracy | 0.5s Grade |
Interface | RS485, Infrared |
Protocol | Modbus-RTU |
Temperature | 3 Channels of Ntc |
Harmonic | 2-31st |
Transport Package | Carton |
Specification | ADL3000=DTSD1352-C |
Trademark | Acrel |
Origin | China |
HS Code | 9028301400 |
Production Capacity | 200000 |
Packaging & Delivery
Package size per unit product 17.00cm * 15.00cm * 13.00cm Gross weight per unit product 0.500kgProduct Description
ADL3000-E is a smart meter designed for power supply systems, industrial and mining enterprises, and utilities to calculate electricity consumption and manage the electric demand. It features high precision, small size, and simple installation. DTSD1352 can be used in all kinds of control systems, SCADA systems, and energy management systems. All meters meet the related technical requirements of electronic power meters in the IEC62053-21, IEC62053-22 standards.
Function
Dimension
Wiring
Installation
Networking
Q: I bought a three-phase four-wire meter, can it be wired as a three-phase three-wire?
A: Yes, press the key to set the meter to three-phase three-wire mode.
Q: What is the difference between ordinary secondary access and -CT (model external transformer)?
A: Ordinary secondary meter could access the ratio XXX/5(1)A of the CTs which could be actual current on-site, the -CT model comes with an external transformer will be convenient for installation(It cannot be disassembled, otherwise it will burn the meter). There are CTs available on site to facilitate with No stitch removal.
Q: What are 3*100V,3*57.7/100V,3*380V,3*220/380V?
A:3*100V, 3*57.7/100V are used for high voltage, used in conjunction with voltage transformers, where 3*100V represents 3P3W,3*57.7V/100V represents 3P4W; 3*380V, 3*220V/380V is used for low voltage, direct voltage input, among them3*380V represents 3P3W, 3*220V/380V represents 3P4W.
Q: Can this meter communicate with PLC?
A: Yes, only need PLC to support RS485 interface, Modbus RTU, or DL/T645 protocol.
Product Parameters
1. Function description
Function | Function description | Function provides |
Measurement of kWh | Active kWh (positive and negative) | standard |
Reactive kWh (positive and negative) | standard | |
A, B, C phase positive active kWh | standard | |
Measurement of electrical parameters | U,I,P,Q,S,PF,F | standard |
standard | ||
Measurement of | 2~31ST Voltage and current harmonic | optional |
LCD Display | 8 bits section LCD display, background light | standard |
Key programming | 4 keys to communication and set parameters | standard |
Pulse output | Active pulse output | standard |
Reactive pulse output | optional | |
Clock pulse output | optional | |
Multi-tariff and functions | Active switch input | optional |
Switch output | optional | |
Adapt 4 time zones, 2 time interval lists, 14 time intervals by day, and 4 tariff rates | optional | |
Max demanded kWh and time happened | optional | |
Frozen data on last 48 months, last 90days | optional | |
Date, time | optional | |
Communication | Infrared communication | standard |
The first communication path: Communication interface: RS485, Communication protocol: MODBUS-RTU | optional | |
The second communication path: Communication interface: RS485, Communication protocol: MODBUS-RTU | optional | |
Temperature measurement | Support 3 outlay NTC temperature | optional |
2. Technical parameter
Specification | 3 phase 3 wires, 3 phase 4 wires | |
Voltage | Reference voltage | 3×100V, 3×380V,3×57.7/100V, 3×220/380V |
Consumption | <10VA(Single phase) | |
Impedance | >2MΩ | |
Accuracy class | Error±0.2% | |
Current | Input current | 3×1(6)A (second connection with 3- phase load line via extra selected CTs) 3×10(80)A (direct connection with 3-phase load line via CTs built-in ADL3000-E) |
Consumption | <1VA(Single phase rated current) | |
Accuracy class | Error±0.2% | |
Power | Active, reactive, apparent power, error±0.5℅ | |
Frequency | 45~65Hz, Error±0.2% | |
Temperature | -40ºC~99ºC | |
Energy | Active energy(Accuracy class:0.5, 1), reactive energy(Accuracy class 2) | |
Clock | ≤0.5s/d | |
Energy pulse output | 1 active optocoupler output, 1 reactive optocoupler output | |
Switching output | 1 Switching output | |
Switching input | 1 optocoupler input | |
Width of pulse | 80±20ms | |
Pulse constant | 6400imp/kWh,400imp/kWh(Correspond with the basic current) | |
Interface and communication | RS485:Modbus RTU | |
Range of communication address | Modbus RTU:1~ 247; | |
Baud rate | 1200bps~19200bps | |
Relative temperature | -25ºC~+55ºC | |
Relative humidity | ≤95℅(No condensation) |
Certifications
ADL | CE |
Company Profile
Acrel[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors. Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.The company attaches great importance to product quality and innovation. By the end of 2018, the company has 5 trademarks, 18 invention patents, 72 utility model patents, 94 appearance patents, and 147 computer software Copyrights, and has participated in the formulation of national or industrial standards.