IEC Approval 5g Tower Base 6 Circuit DC Smart Energy Power Meter for China Telecom Amc16-Dett

IEC Approval 5g Tower Base 6 Circuit DC Smart Energy Power Meter for China Telecom Amc16-Dett

Product Description IEC approval 5G tower base 6 circuit DC smart energy power meter AMC16-DETT AMC16-DETT is designed s;
Basic Info
Model NO. AMC16-DETT
Measured Signal Continuous Wave
Type Energy Meter
Certification IEC
Customized Non-Customized
DC Voltage -48VDC
DC Current 6 Channel DC200A/5V
Grid Power Monitoring 1 Channel 0-5V DC
Communication Modbus RTU RS485
Application Base Station
Power Supply -40~-60VDC
Warranty 2 Years
Default Baud Rate 9600BPS
Transport Package Paper Cartpn
Specification 134*246mm
Trademark ACREL
Origin Jiangsu, China
HS Code 9030849000
Production Capacity 1000PCS/Week
Product Description
Product Description

IEC approval 5G tower base 6 circuit DC smart energy power meter AMC16-DETT

AMC16-DETT is designed special for China tower metering,ACREL 6 circuit dc power meter is for China Telecom, China Mobile, China Unicom,and other telecommunication tower metering.
Base station dedicated DC energy meter AMC16-DETT is specially designed for base stations where have sharing requirements, and switch power supply is without the function of sub-user metering.

The meter could measure 6 circuits DC energy, and supply working current to the matched hall sensors. Meanwhile, it can realize zero drift calibration by upper computer software. have the functions of telemetering,teleindication,teleadjusting, metering at real time, energy quality abnormal alarm, data storage and processing, data interaction.

This meter can measure DC power consumption of three operators, providing detail data for base station.

Functions and Parameters

Functions of AMC16-DETT dc energy power meter

*DC rated voltage:1 circuit -48VDC

*DC current :6 channel hall current sensor,total DC200A/5V,China Telecom, China Mobile, China Unicom and the 1st channel reserve 50A/5V, 2nd channel reserve 100A/5V.

*Communication: RS485,default baud rate:9600bps

*Main functions:Monitoring equipment system time, total voltage,output current, power and energy, each circuit voltage, current,power and energy,LED display

*Alarm function:DC low voltage output alarm,DC high voltage output alarm,one power down alarm, module voltage loss alarm, metering branch error alarm, internal program error alarm, clock error alarm, memory failure alarm and AC input power failure alarm

*Timing function:support broadcast timing, could remote timing to the meter by RS485*Lightening protection(SPD module)

*Clamps power supply:Power supply output:+12V/100Ma, -12V/50mA

*Power supply for the meter:-40~-60VDC

Input

DC voltage

1 channel: -48VDC

DC current

6 channel hall current sensor,total DC200A/5V,China Telecom, China Mobile, China Unicom and the 1st channel reserve 50A/5V, 2nd
channel reserve 100A/5V.

Grid power
monitoring

1 channel: 0-5VDC

Overload capacity

Voltage:1.2times continued,2 times continued 1s;
Current: 1.2 times continued,10 times continued 1s.

Accuracy (superposition hall sensors)

1%In≤I≤10%In error±2.5%; I>10%In error±2%

resolution

Voltage output accuracy 0.01V; current output accuracy 0.01A;
power output accuracy 0.01kw; energy output accuracy 0.01kwh

Functions

Basic function

Monitor device system time, total voltage, output total current,
power, energy, each channel voltage, current, power, energy; LED
indicator display;485 communication

Metering function

Start current: under rated voltage, when the load current value of
the meter doesn't exceed 1% of the max. current, the meter
starts.
Shunt running current: when there is no current in the current
circuit of the meter, and 85%-125%of the rated voltage is applied
on the voltage circuit, the calculator shall not have more than

Alarm function

DC low voltage output alarm,DC high voltage output alarm,one power down alarm, module voltage loss alarm, metering branch error
alarm, internal program error alarm, clock error alarm, memory failure alarm and AC input power failure alarm

Timing function

support broadcast timing, could remote timing to the meter by RS485

Hall CT power supply

:Power supply output:+12V/100Ma, -12V/50mA

Clock accuracy

≤0.5s/d(23ºC),≤1s/d(-20ºC~60ºC)

Powe supply for ther meter

-40VDC~ -60VDC

Power consumption

≤2W


Dimensions and Wirings

IEC Approval 5g Tower Base 6 Circuit DC Smart Energy Power Meter for China Telecom Amc16-Dett

ACREL recommended Hall CTs (Unit:mm) AHKC-EKA,AHKC-EKB or AHKC-K

IEC Approval 5g Tower Base 6 Circuit DC Smart Energy Power Meter for China Telecom Amc16-Dett

IEC Approval 5g Tower Base 6 Circuit DC Smart Energy Power Meter for China Telecom Amc16-Dett

About ACREL

Professional manufacturer with over 18 years experience in energy meters

IEC Approval 5g Tower Base 6 Circuit DC Smart Energy Power Meter for China Telecom Amc16-Dett

IEC Approval 5g Tower Base 6 Circuit DC Smart Energy Power Meter for China Telecom Amc16-Dett

FAQ

Q:Where is your company located?
A:Our headquarter is in Shanghai, our factory locates in Jiangyin,Jiangsu Province,China.It takes about 1 hour by car from Shanghai Hongqiao International Airport to our factory. As it is low labor cost here in Jiangsu,we can offer a better price with high quality. A:Our headquarter is in Shanghai, our factory locates in Jiangyin,Jiangsu Province,China.It takes about 1 hour by car from Shanghai Hongqiao International Airport to our factory. As it is low labor cost here in Jiangsu,we can offer a better price with high quality.
Q:What's your lead time?
A:Sample time 1-3days,mass production 10~20days for order more than 500pcs Q:Payment terms?
A:Usually,TT,credit card,western union,in cash and so on.You can also choose to pay 30% as deposit and the balance before shipment or against copy of B/L if the order is large.
Q:Can other logo be put on your products(ODM)?
A:Yes,but MOQ for ODM will be at least 5pcs.We also need you provide logo Ai Format or EPS.
Send inquiry